Power Adders Technical discussions for forced induction with nitrous and blowers.

No more flex on bracket install for Procharger

Thread Tools
 
Search this Thread
 
  #1  
Old 07-21-2006 | 10:17 AM
Stangdude27's Avatar
Thread Starter
|
Silver 2003 GT Conv
Joined: Nov 2004
Posts: 399
From: Ft Walton Beach,Florida
Default No more flex on bracket install for Procharger

here is the pics
 
Attached Images
File Type: jpg
100_0942.JPG (17.8 KB, 40 views)
File Type: jpg
100_0945.JPG (47.9 KB, 37 views)
File Type: jpg
100_0943.JPG (34.4 KB, 35 views)
  #2  
Old 07-21-2006 | 10:19 AM
Stangdude27's Avatar
Thread Starter
|
Silver 2003 GT Conv
Joined: Nov 2004
Posts: 399
From: Ft Walton Beach,Florida
Default

Tkae the offset bushing and get it firmly seated on the alt footing. Then install washer to the striaght bolt that goes from the head unit housing to the offset. You'll need size 8 washers but it should mount no problem. Also check and make sure the other 2 bolts on the braket are flush with the idler pulley. More wahser are needed for alignment but this should solve the problems with mounting this unit with no flex. Also if needed contact Dave Guy at kauffman motorsports in dillsburg,PA. The took about an hour to get this working the correct way.
 
  #3  
Old 07-21-2006 | 10:28 AM
Stangdude27's Avatar
Thread Starter
|
Silver 2003 GT Conv
Joined: Nov 2004
Posts: 399
From: Ft Walton Beach,Florida
Default

Keep in mind I have the 8 rib kit so the 6 rib will vary in washer's needed. Also some slight grinding was need on my 2.9 pulley to get it to clear the alt. But as long as you check the alignment of the bracket and the pulley this little bit of info should help.
 
  #4  
Old 07-21-2006 | 10:34 AM
Stangdude27's Avatar
Thread Starter
|
Silver 2003 GT Conv
Joined: Nov 2004
Posts: 399
From: Ft Walton Beach,Florida
Default

pointed to washers
 
Attached Images
File Type: jpg
100_0942.JPG (18.8 KB, 17 views)
File Type: jpg
100_0943.JPG (35.7 KB, 25 views)
File Type: jpg
100_0945.JPG (53.6 KB, 31 views)
  #5  
Old 07-23-2006 | 03:22 PM
foncarelli's Avatar
Everyday Im Hustlin
Joined: Jun 2005
Posts: 3,970
From: Ecorse, Michigan
Default

That seems to be holding up so far. I also found this thread for a tensioner mod: http://forums.modulardepot.com/showt...t=78624&page=3

Im gonna try that too.

Thanks for your help. They should make this a sticky.
 
  #6  
Old 08-11-2006 | 12:21 AM
foncarelli's Avatar
Everyday Im Hustlin
Joined: Jun 2005
Posts: 3,970
From: Ecorse, Michigan
Default

Thanks a lot, Wade. I didnt need as many washers as you, but everything is holding up just fine. Now that i have the bracket problem taken care of, i am starving for fuel at 4500rpms. I am going to start shopping for a KB BAP.
 
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Steve@CJPP
Sponsors
0
10-30-2014 09:27 AM
Silver GT
Power Adders
3
08-04-2009 08:20 AM
Must See
The Lounge
4
06-28-2008 08:55 PM




All times are GMT -7. The time now is 10:26 PM.